6 POSITIONING CONTROL
PLC ready flag (M2000)
All axes servo ON command
(M2042)
All axes servo ON accept flag
(M2049)
Axis 4 servo ready (M2475)
Start command (PX000)
Servo program start
Axis 4 start accept flag
(M2004)
End command (PX001)
(3) Operation timing
Operation timing for fixed-pitch feed control is shown below.
V
10000
(4) Servo program
Servo program No.300 for fixed-pitch feed control is shown below.
<K 300>
FEED-1
Axis
Speed
Dwell
(Note): Example of the Motion SFC program for positioning control is shown next page.
Servo program No.300
Dwell 1second
Dwell 1second
1 axis fixed-pitch feed
4,
80000
10000
1000
6 - 81
Dwell 1second
Axis used . . . . . . . . . . Axis 4
Travel value . . . . . . . . 80000
. . . 10000
Command speed
Dwell . . . . . . . . . . . . . . 1000