c) "Servo parameter write/read" device
Store the value in the following special registers to change or display
the servo parameter.
Name
Meaning
Servo parameter
read value
Servo parameter
write/read request
flag
Axis No.
Servo parameter
No.
Servo parameter
setting value
(2 word)
(g) Optional data monitor setting
The following table shows data types that can be set.
Set the data so that the total number of communication points per axis is no
more than 6 points.
Data type
Position F/B
Cumulative current value
(Note-1): The position command is the command unit set in the fixed parameter.
(h) Gain changing command, PI-PID switching command, control loop changing
command
Gain changing command, PI-PID switching command, and control loop
changing command becomes invalid.
• The read value (low 1 word) of servo parameter
which executed "4: 2 word read request" in SD804 is
stored.
• The read value (high 1 word) of servo parameter
which executed "4: 2 word read request" in SD804 is
stored.
• The "write/read request" is executed after setting of
the axis No. and servo parameter No.
3: 2 word write request
4: 2 word read request
• "0" is automatically set by Motion CPU after
completion of servo parameter write/read request.
("-1" is stored by Motion CPU at write/read error.)
• The axis No. to write/read servo parameter is stored.
Q173DSCPU: 1 to 32
Q172DSCPU: 1 to 16
• The servo parameter No. to be written/read is stored
in hexadecimal.
H
Parameter No. ID
(Note): Refer to IAI electric actuator controller
instruction manual for details.
• The setting value of servo parameter to be written is
stored when "3: 2 word write request" is set in
SD804.
Unit
[pulse]
[Position
command]
APP - 129
Details
(Note)
(Note-1): Do not execute the automatic refresh.