APPENDICES
QDS
(c) Control mode
Control modes that can be used are shown below.
• Position control mode (position control, and speed control including
position loop)
• Speed control mode (speed control not including position loop)
• Torque control mode (torque control)
However, it is not available to switch to continuous operation to torque
control mode of "Speed-torque control". If the mode is switched to
continuous operation to torque control mode, a minor error (error code: 318)
occurs and the operation stops.
"1: Feedback torque" cannot be set in "Torque initial value selection at
control mode switching". If it is set, a minor error (error code: 154) occurs
and the command value immediately after switching is the same as the case
of selecting "0: Command torque".
(d) Servo parameter
1) Control of servo parameters
Parameters of VC series/VPH series are not controlled by Motion CPU.
Therefore, even though the parameter of VC series/VPH series is
changed during the communication between Motion CPU and VC
series/VPH series, it does not process, and is not reflected to the
parameter.
2) Servo parameter change function
a) Change function of servo parameter can be executed.
The following is the operation for the servo parameter change
function.
The servo parameter of VC series/VPH series is controlled in a unit of 2 words, so that it is
Servo
necessary to set "3: 2 words write request" in servo parameter write/read request (SD804)
parameter
for executing the parameter write. If "1: write request" is executed to VC series/VPH
write request
series, the parameter write fails, and "-1" is stored in servo parameter write/read request
(SD804).
The servo parameter of VC series/VPH series is controlled in a unit of 2 words, so that it is
Servo
necessary to set "4: 2 words read request" in servo parameter write/read request (SD804)
parameter read
for executing the parameter read. If "2: read request" is executed to VC series/VPH
request
series, the parameter read fails, and "-1" is stored in servo parameter write/read request
(SD804).
b) When the servo parameter of VC series/VPH series is changed by
the servo parameter change function, the parameter value after
changing the servo parameter cannot be confirmed using VC /VPH
data editing software. When confirming the parameter value,
execute the servo parameter read request. Also, when the power of
VC series/VPH series is turned OFF, the parameter changed by
the servo parameter change function becomes invalid, and the value
written by VC /VPH data editing software becomes valid.
Operation for the servo parameter change function