3 POSITIONING DEDICATED SIGNALS

3.2.2 Control change registers

Name
Axis 1
D641, D640 D643, D642 D645, D644 D647, D646 D649, D648 D651, D650 D653, D652 D655, D654
Axis 9
D657, D656 D659, D658 D661, D660 D663, D662 D665, D664 D667, D666 D669, D668 D671, D670
JOG speed
setting
Axis 17
register
D673, D672 D675, D674 D677, D676 D679, D678 D681, D680 D683, D682 D685, D684 D687, D686
Axis 25
D689, D688 D691, D690 D693, D692 D695, D694 D697, D696 D699, D698 D701, D700 D703, D702
Unit
Item
Setting range
1 to
JOG speed
600000000
(Note-1) : When the " speed control 10
" 10
(13) Real current value at STOP input storage register
(D18+20n, D19+20n) .............................................. Monitor device
This register stores the real current value at the detection of a stop/rapid stop
cause.
This area stores the JOG operation speed data.
Table 3.1 Data storage area for control change list
Axis 2
Axis 3
Axis 10
Axis 11
Axis 18
Axis 19
Axis 26
Axis 27
(1) JOG speed setting registers (D640+2n, D641+2n)
(a) This register stores the JOG speed at the JOG operation.
(b) Setting range of the JOG speed is shown below.
mm
Unit
Setting range
-2
10
1 to
[mm/min]
600000000
multiplier setting for degree axis" is set to "valid" in the fixed parameter, the unit is
-2
[degree/min] ".
(c) The JOG speed is the value stored in the JOG speed setting registers
(D640+2n, D641+2n) at leading edge of JOG start signal.
Even if data is changed during JOG operation, JOG speed cannot be
changed.
(d) Refer to Section 6.21 for details of JOG operation.
Axis 4
Axis 5
Axis 12
Axis 13
Axis 20
Axis 21
Axis 28
Axis 29
(Note): The following range is valid.
inch
Unit
Setting range
-3
10
1 to
[inch/min]
2147483647
3 - 55
Axis 6
Axis 7
Axis 14
Axis 15
Axis 22
Axis 23
Axis 30
Axis 31
• Q172DSCPU
• Q172DCPU(-S1) : Axis No. 1 to 8
........................ Command device
degree
(Note-1)
Unit
Setting range
-3
10
1 to
[degree/min]
2147483647
Axis 8
Axis 16
Axis 24
Axis 32
: Axis No. 1 to 16
pulse
Unit
[pulse/s]