APPENDICES
(2) Parameter setting
(a) To connect VC series, set the following in the system setting of
MT Developer2.
1) When using Q173DSCPU/Q172DSCPU
• Set the following for communication type in SSCNET setting.
• When connecting SSCNET /H : "SSCNET /H"
• When connecting SSCNET
• Set the amplifier model in amplifier setting to "VC (CKD Nikki
Denso)".
• Set the ABS/INC setting in amplifier setting to "INC", or "ABS".
2) When using Q173DCPU(-S1)/ Q172DCPU(-S1)
• Set the amplifier model in amplifier setting to "VC (CKD Nikki
Denso)".
• Set the ABS/INC setting in amplifier setting to "INC", or "ABS".
POINT
Match the ABS/INC setting with the setting of VC series. Otherwise, it does not
operate correctly.
(b) To connect VPH series, set the following in the system setting of
MT Developer2.
• Set the following for communication type in SSCNET setting.
• When connecting SSCNET /H : "SSCNET /H"
• When connecting SSCNET
• Set the amplifier model in amplifier setting to "VPH (CKD Nikki Denso)".
(3) Control of VC series/VPH series parameters
Parameters set in VC series/VPH series are not controlled by the Motion CPU.
They are set directly using VC /VPH data editing software. For details on setting
items for VC series/VPH series, refer to the instruction manual of VC
series/VPH series.