7 AUXILIARY AND APPLIED FUNCTIONS
(c) When the M-code is read at positioning completion, use the positioning
complete signal (M2401+20n) as the read command.
At the position control or speed control
PLC ready flag (M2000)
Servo program start
Start accept flag (M2001+n)
Positioning start complete
signal (M2400+20n)
Positioning complete
signal (M2401+20n)
M-code
At the speed switching control
PLC ready flag (M2000)
Servo program start
Start accept flag (M2001+n)
Positioning start complete
signal (M2400+20n)
Positioning complete
signal (M2401+20n)
M-code
(3) Resetting of M-codes
M-codes can be reset by setting of the M-code output devices to zero.
Use this method during positioning control to perform operations unrelated to the
servo program, such as when it has been difficult to output the M-code during the
previous positioning control.
However, M-code is set during the speed switching control or constant-speed
control, the M-code output of the servo program takes priority.
V
ON
OFF
ON
OFF
ON
OFF
OFF
Storage of setting M-code No.
V
P1 (Speed-switching point)
ON
OFF
ON
OFF
ON
OFF
OFF
7 - 2
Dwell time
t
ON
P2 (Speed-switching point)
P3 (Stop)
t
ON
Storage of setting M-code No.