Mitsubishi Electric MELSEC Q Series Programming Manual page 106

Motion controller, real mode
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

3 POSITIONING DEDICATED SIGNALS
(3) Manual pulse generator axis No. setting registers (D714 to D719)
(a) These registers stores the axis No. controlled with the manual pulse
generator.
b15
b14 b13 b12 b11 b10
D714
Axis 16 Axis 15 Axis 14 Axis 13 Axis 12 Axis 11 Axis 10 Axis 9 Axis 8 Axis 7 Axis 6 Axis 5 Axis 4 Axis 3 Axis 2 Axis 1
P1
D715
Axis 32 Axis 31 Axis 30 Axis 29 Axis 28 Axis 27 Axis 26 Axis 25 Axis 24 Axis 23 Axis 22 Axis 21 Axis 20 Axis 19 Axis 18 Axis 17
D716
Axis 16 Axis 15 Axis 14 Axis 13 Axis 12 Axis 11 Axis 10 Axis 9 Axis 8 Axis 7 Axis 6 Axis 5 Axis 4 Axis 3 Axis 2 Axis 1
P2
D717
Axis 32 Axis 31 Axis 30 Axis 29 Axis 28 Axis 27 Axis 26 Axis 25 Axis 24 Axis 23 Axis 22 Axis 21 Axis 20 Axis 19 Axis 18 Axis 17
D718
Axis 16 Axis 15 Axis 14 Axis 13 Axis 12 Axis 11 Axis 10 Axis 9 Axis 8 Axis 7 Axis 6 Axis 5 Axis 4 Axis 3 Axis 2 Axis 1
P3
D719
Axis 32 Axis 31 Axis 30 Axis 29 Axis 28 Axis 27 Axis 26 Axis 25 Axis 24 Axis 23 Axis 22 Axis 21 Axis 20 Axis 19 Axis 18 Axis 17
(b) Refer to Section 6.22 for details of the manual pulse generator operation.
(4) Manual pulse generator 1-pulse input magnification setting
registers (D720 to D751) ..................................... Command device
(a) These register set the magnification (1 to 10000) per pulse of number of the
input pulses from manual pulse generator at the pulse generator operation.
1-pulse input
magnification
Axis No.
setting register
D720
Axis 1
D721
Axis 2
D722
Axis 3
D723
Axis 4
D724
Axis 5
D725
Axis 6
D726
Axis 7
D727
Axis 8
D728
Axis 9
D729
Axis 10
D730
Axis 11
D731
Axis 12
D732
Axis 13
D733
Axis 14
D734
Axis 15
D735
Axis 16
(b) Refer to Section 6.22 for details of the manual pulse generator operation.
........................ Command device
b9
b8
(Note-1): Make the axis No. controlled with the manual pulse generator
setting with 1/0.
1 : Specified axis
0 : Unspecified axis
(Note-2): The following range is valid.
Q172DSCPU
: Axis No.1 to 16
Q172DCPU(-S1) : Axis No.1 to 8
1-pulse input
Setting range
magnification
setting register
1 to 10000
3 - 57
b7
b6
b5
b4
b3
b2
Axis No.
D736
Axis 17
D737
Axis 18
D738
Axis 19
D739
Axis 20
D740
Axis 21
D741
Axis 22
D742
Axis 23
D743
Axis 24
D744
Axis 25
D745
Axis 26
D746
Axis 27
D747
Axis 28
D748
Axis 29
D749
Axis 30
D750
Axis 31
D751
Axis 32
(Note): The following range is valid.
• Q172DSCPU
• Q172DCPU(-S1) : Axis No. 1 to 8
b1
b0
Setting range
1 to 10000
: Axis No. 1 to 16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents