Mitsubishi Electric MELSEC Q Series Programming Manual page 331

Motion controller, real mode
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

6 POSITIONING CONTROL
[Control details]
Start and end for 2 to 4 axes constant-speed control
2 to 4 axes constant-speed control is started and ended using the following
instructions:
(1) CPSTART2
Ver.!
Starts the 2 axes constant-speed control. Sets the axis No. and command speed.
(2) CPSTART3
Ver.!
Starts the 3 axes constant-speed control. Sets the axis No. and command speed.
(3) CPSTART4
Ver.!
Starts the 4 axes constant-speed control. Sets the axis No. and command speed.
(4) CPEND
Ends the 2, 3, or 4 axes constant-speed control for CPSTART2, CPSTART3, or
CPSTART4.
Positioning control method to the pass point
Positioning control to change control is specified using the following instructions:
(1) ABS-2/INC-2
Sets 2 axes linear interpolation control.
Refer to Section 6.3 "2 Axes Linear Interpolation Control" for details.
(2) ABS-3/INC-3
Sets 3 axes linear interpolation control.
Refer to Section 6.4 "3 Axes Linear Interpolation Control" for details.
(3) ABS-4/INC-4
Sets 4 axes linear interpolation control.
Refer to Section 6.5 "4 Axes Linear Interpolation Control" for details.
(4) ABS/INC
Sets circular interpolation control using auxiliary point specification.
Refer to Section 6.6 "Auxiliary Point-Specified Circular Interpolation Control" for
details.
(5) ABS/INC
, ABS/INC
Sets circular interpolation control using radius specification.
Refer to Section 6.7 "Radius-Specified Circular Interpolation Control" for details.
Ver.!
: Refer to Section 1.3 for the software version that supports the advanced
S-curve acceleration/deceleration in constant-speed (CPSTART).
, ABS/INC
6 - 144
, ABS/INC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents