Mitsubishi Electric MELSEC Q Series Programming Manual page 192

Motion controller, real mode
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

6 POSITIONING CONTROL
POINTS
(1) Speed limit value and positioning speed
• The setting speed limit value applies to the long-axis speed.
• Be careful that the vector speed may exceed the speed limit value at the
long-axis speed specification.
Example
The following settings at the 2 axes linear interpolation, the vector speed
exceeds the speed limit value.
Axis 1 travel value : 100 [pulse]
Axis 2 travel value : 200 [pulse]
Long-axis speed : 50 [pulse/s]
Speed limit value : 55 [pulse/s]
In this example, since the reference-axis is
axis 2 of the largest travel value, it is
controlled with the speed limit value specified
with axis 2.
The positioning speed and vector speed for
each axis are as follows:
Axis 1 positioning speed : 100/ 200
Axis 2 positioning speed : 50 [pulse/s]
2
25 + 50 = 55.9[pulse/s]
Vector speed :
Axis 1 positioning
speed
Axis 2 positioning speed
The vector speed exceeds the speed limit value setting of 55.
(2) Relationship between speed limit value, acceleration time, deceleration time
and rapid stop deceleration time.
• The real acceleration time, deceleration time and rapid stop deceleration
time are set by the setting long-axis speed.
Speed
1)
2)
50 = 25 [pulse/s]
2
Vector speed
Speed limit value
Positioning speed(long-axis speed)
Rapid stop cause occurrence
1) Real acceleration time
2) Setting acceleration time
3) Real deceleration time
Time
4) Setting deceleration time
3)
5) Real rapid stop deceleration time
5)
6) Setting rapid stop deceleration time
6)
4)
6 - 5
<K 2>
INC-2
Axis
1,
100
Axis
2,
200
Long-axis speed
50
[pulse]
[pulse]
[pulse/s]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents