Mx2008 Three-Phase Wye Ac Power Distribution Module Description - Juniper MX2008 Hardware Manual

Universal routing platform
Hide thumbs Also See for MX2008:
Table of Contents

Advertisement

MX2008 AC Power Requirements | 74
MX2008 AC Power System Electrical Specifications | 85
MX2008 AC Power Cord Specifications | 82

MX2008 Three-Phase Wye AC Power Distribution Module Description

NOTE:
The MX2008, MX2010, and MX2020 routers support the same power modules (AC/DC
PSMs and AC/DC PDMs).
Each three-phase wye AC PDM weighs approximately 12 lb (5.44 kg). A metal wiring compartment contains
two AC terminal blocks and ground labeled GND. One AC terminal block consists of three input terminals
that serve six PSMs and the second terminal block serves three PSMs. The terminal block on the far left
is labeled A1, B1, C1, and N1 (bottom to top). The second terminal block is labeled A2, B2, C2, and N2
(bottom to top). The PDMs are located at the rear of the chassis in slots PDM0/Input0 through
PDM1/Input1, (bottom to top). LEDs provide the status of the PDM.
three-phase wye AC PDM.
NOTE:
The three-phase wye AC PDM terminal blocks will be flipped depending on which slot
the PDM gets plugged into.
Figure 25: Three-Phase Wye AC Power Distribution Module
Figure 26 on page 70
shows the three-phase wye AC PDM connections.
Figure 25 on page 69
shows the
69