4. Check the OK/FAIL LED on the MPC, and the OK and FAIL line-card LEDs, LC0 through LC9, on the
craft interface. When the MPC is online and functioning normally, the OK LED lights green steadily.
5. Check the status of an MPC by using the show chassis fpc CLI command. As shown in the sample
output, the value Online in the column labeled State indicates that the MPC is functioning normally:
user@host> show chassis fpc
Temp
Slot State
0
Online
1
Online
2
Online
3
Empty
4
Online
5
Empty
6
Empty
7
Empty
8
Empty
9
Online
Use the detail option to display more detailed information. The following example does not specify a
slot number, which is optional:
For further description of the command output, see the
user@host> show chassis fpc detail
Slot 0 information:
State
Temperature
Total CPU DRAM
Total RLDRAM
Total DDR DRAM
Start time:
Uptime:
Max Power Consumption
Slot 1 information:
State
Temperature
Total CPU DRAM
Total RLDRAM
Total DDR DRAM
CPU Utilization (%)
(C)
Total
Interrupt
37
8
35
6
37
9
37
9
37
11
26
2048 MB
403 MB
1572 MB
249 Watts
25
2048 MB
662 MB
3072 MB
Memory
Utilization (%)
DRAM (MB) Heap
0
2048
0
2048
0
2048
0
2048
0
2048
Junos OS System Basics Configuration
Online
2017-02-20 02:21:40 PST
5 hours, 28 minutes, 57 seconds
Online
Buffer
10
13
13
13
17
13
17
13
21
13
Guide.