You can use cable strips or other ties to gently secure the cables in the DC cable manager. To secure the
cables in place, loop the tie through the cable anchor and secure the tie. You can pull the DC cable manager
up and outward to lock it into the maintenance position.
Figure 11: MX2008 Standard Cable Manager
Front bottom
Rear DC Cable (for DC PDM)
Figure 12: Lower Cable Manager
The card-cage cable manager (see
Figure 13 on page
52) is located in the upper card cage, which has rows
for routing and securing the cables away from the front of the RCBs and SFBs.
You can use cable strips or other ties to gently secure the cables in the card-cage cable manager. To secure
the cables in place, loop the tie through the cable anchor and secure the tie. To access the air filter, the
cable manager needs to be opened.