Issue the show chassis alarms command to view the alarms.
SEE ALSO
MX2008 Host Subsystem Description | 123
Troubleshooting the MX2008 MICs
Problem
Description: A MIC LED lit red indicates a problem with the MIC.
Solution
To troubleshoot a MIC:
1. Check the status of each port on a MIC by looking at the LED located on the MIC faceplate. For
information about the meaning of LED states on different MICs, see the
Reference
2. Check the status of a MIC by issuing the show chassis fpc pic-status CLI command. The MIC slots in
the MPC are labeled PIC 0/1 and PIC 2/3, top to bottom:
user@host> show chassis fpc pic-status
Slot 0
Online
PIC 0
Online
PIC 1
Online
PIC 2
Online
PIC 3
Online
Slot 1
Online
PIC 2
Online
PIC 3
Online
Slot 2
Online
PIC 0
Online
PIC 1
Online
PIC 2
Online
Slot 9
Online
PIC 0
Online
PIC 1
Online
PIC 2
Online
PIC 3
Online
MPCE Type 1 3D Q
10x 1GE(LAN) SFP
10x 1GE(LAN) SFP
1x 10GE XFP
1x 10GE XFP
MPCE Type 2 3D
2x 10GE
XFP
2x 10GE
XFP
MPCE Type 3 3D
1x 10GE XFP
1x 10GE XFP
1X100GE CFP
MPC 3D 16x 10GE EM
4x 10GE(LAN) SFP+
4x 10GE(LAN) SFP+
4x 10GE(LAN) SFP+
4x 10GE(LAN) SFP+
MX Series Interface Module