If the OK/FAIL LED is red, remove and install the SFB again. If the OK/FAIL LED still lights steadily,
the SFB is not functioning properly. Contact your customer support representative. See Contacting
Customer Support.
7. Check the status of the SFB by using the show chassis sfb command:
user@host> show chassis sfb
Slot
State
0
Online
1
Offline
2
Online
3
Online
4
Offline
5
Online
6
Offline
7
Online
Figure 175: Installing an SFB
SEE ALSO
MX2008 Enhanced Switch Fabric Board (MX2008 SFB2) Description | 159
Preventing Electrostatic Discharge Damage to an MX2008 Router | 544
Uptime
2 hours, 22 minutes, 15 seconds
--- Offlined by cli command ---
2 hours, 22 minutes, 6 seconds
2 hours, 21 minutes, 59 seconds
--- Offlined by cli command ---
2 hours, 21 minutes, 49 seconds
--- Offlined by cli command ---
2 hours, 21 minutes, 35 seconds