Basic software procedures
Ê Under Retry counter max specify the maximum number of attempts to boot
the operating system (0 to 7).
Ê Under Retry counter the current number of remaining boot attempts is
displayed. Overwrite this value with the maximum number of boot
attempts specified above in order to reset the boot retry counter.
Ê Click Apply for the changes to take effect.
I
For detailed information on iRMC settings, refer to the "Integrated
Remote Management Controller" user guide.
5.2.7
Resetting the error status after replacing memory
modules or processors
5.2.7.1

Memory modules

ServerView Operations Manager may report a defective memory module in
case of a memory error.
I
Important note
After replacing a defective memory module, please check if the error
counter has been reset automatically. If the memory slot is still marked
as failed, please reset the error counter manually using one of the
methods below.
Using the iRMC web frontend
Ê Enter the ServerView iRMC web frontend.
Ê Select the System Information menu.
Ê Under System Components, select the check boxes next to the affected
memory modules.
Ê From the drop down list, select Reset Error Counter.
Ê Click Apply for the changes to take effect.
Using ServerView Maintenance Tools (Windows only)
Ê Launch the ServerView Maintenance Tools:
– Windows Server 2008 R2 and below:
Start > (All) Programs > Fujitsu > ServerView Suite > Agents >
Maintenance Tools