Resetting The Error Status After Replacing Memory Modules Or Cpu; Resetting The Error Status After Replacing Cpus - Fujitsu PRIMERGY RX4770 M5 Upgrade And Maintenance Manual

Table of Contents

Advertisement

▶ Exit the BIOS.
Resetting the boot retry counter using the ServerView Operations
Manager
▶ In the ServerView Operations Manager Administration view, select Server
Configuration.
▶ If more than one server is managed in SVOM, select the target server and
click Next.
▶ From the Server Configuration menu pane, choose Restart Options.
▶ Under Reboot Retries, specify the maximum number of boot attempts (0 to
7) in the Default for reboot tries field.
Resetting the boot retry counter using iRMC web interface
▶ Enter the ServerView iRMC web interface.
▶ Select the Server Management menu.
▶ The following boot retry counter settings are available under ASR&R
Options:
▶ Under Retry counter max specify the maximum number of attempts to
boot the OS (0 to 7).
▶ Under Retry counter the current number of remaining boot attempts is
displayed. Overwrite this value with the maximum number of boot
attempts specified above in order to reset the boot retry counter.
▶ Click Apply for the changes to take effect.
For more information on iRMC settings, see the iRMC user guides.
5.3.7
Resetting the error status after replacing memory
modules or CPU
5.3.7.1

Resetting the error status after replacing CPUs

In case of a CPU error, an error counter may be set for the defective CPU.
RX4770 M5
Upgrade and Maintenance Manual
Basic software procedures
97

Advertisement

Table of Contents
loading