Power Mirror System Symptom Chart - Case IH AFX8010 Repair Manual

Table of Contents

Advertisement

POWER MIRROR SYSTEM SYMPTOM CHART

NOTE: The batteries must be fully charged and all connections clean and tight. Use a multimeter (DVOM) for
these tests. For battery testing and service, see the battery section in the service manual.
DO NOT use a self-powered test light for any of these tests. Use of a self-powered test light can cause
damage to components in this system.
Before performing any of the electrical tests, be sure all operating controls are in neutral or park lock
position. This will eliminate accidental movement of the machine or start-up of power driven equipment.
Symptom
All Power Mirrors inoperable
RH and German Power Mirrors
inoperable
Left Power Mirror inoperable
Right Power Mirror inoperable
German Power Mirror
inoperable
All Heated Mirrors inoperable
LH Heated Mirror inoperable
RH Heated Mirror inoperable
German Heated Mirror
inoperable
BODY AND STRUCTURE - USER PLATFORM
CAUTION
WARNING
Possible Cause
No power or ground to Mirror
Adjust Switch S-27
Mirror Adjust Switch S-27
Mirror Adjust Switch S-27
Mirror Select Switch S-27
Mirror Adjust Switch S-27
Left Mirror Assembly
Right Mirror Assembly
Adjacent circuits
German Mirror Assembly
Adjacent circuits
Mirror Heat Switch S-19
No general power or ground
supply for heating mirrors
Heating element for LH Mirror
Adjacent circuits
Heating element for RH Mirror
Adjacent circuits
Heating element for German
Mirror
Adjacent circuits
E.34 / 19
Reference/Test
A - Mirror Adjust Switch Test
A - Mirror Adjust Switch Test
B - Mirror Select Switch Test
A - Mirror Adjust Switch Test
steps 4-7 and 12-15.
C - LH Power Mirror Test
D - RH Power Mirror Test
E - German Power Mirror Test
F - Mirror Heat Switch Test
G - Heating Mirrors Test steps 1
and 2
G - Heating Mirrors Test steps 1
and 2
G - Heating Mirrors Test steps 3
and 4
G - Heating Mirrors Test steps 5
and 6

Advertisement