BODY AND STRUCTURE - ENVIRONMENT CONTROL Heating, ventilation and air-conditioning
Condenser - Remove (E.40.D.32 - F.10.A.10)
AFX8010
1.
Recover refrigerant in accordance with local
regulations.
2.
Open the rotary screen door to gain access to the
air conditioning condenser.
3.
Disconnect and cap the refrigerant lines from the
condenser (1). The fittings are different sizes,
labeling should not be required.
NOTE: Use the proper tools to remove the lines correctly
and prevent the condenser lines twisting.
4.
Remove the condenser (2) by removing the two
pins (1) from the hinges.
9702 1 27/05/2004
E.40.D / 27
1
40034893A5
2
40034893B5