7.
Disconnect the header (HH) harness to feeder (FE) harness connector X032. Use a multimeter to check for
voltage between the feeder (FE) harness end of connector X032 pin 27 and chassis ground. There should not
be any voltage.
A.
If there is no voltage, there is a short circuit in the header (HH) harness between connector X032 and
connector X435 wire 1116 yellow. Locate the short and repair.
B.
If there is voltage (>4.72 volts), continue with step 5.
8.
Disconnect the feeder (FE) harness to front frame (FF) harness connector X007. Use a multimeter to check
for voltage between the front frame (FF) harness end of connector X007 pin 27 and chassis ground. There
should not be any voltage.
A.
If there is no voltage, there is a short circuit in the feeder (FE) harness between connector X032 and
connector X007 wire 1116 yellow. Locate the short and repair.
B.
If there is voltage (>4.72 volts), there is a short circuit in the front frame (FF) harness between connector
X007 and connector X017 pin J3-24 wire 1116 yellow. Locate the short and repair.
9.
Visually inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or
broken wires.
A.
If no damage is found, erase the fault code and continue operation.
CROP PROCESSING - FEEDING Header feeding
9711 1 27/05/2004