Case IH AFX8010 Repair Manual page 1829

Table of Contents

Advertisement

NOTE: The sense resistor in the module for the Header Raise/Lower Current Sense circuit is easily damaged
as a result of excessive current draw or a short to high voltage.
6.
Turn the key switch to the ON position. Use the Universal Display Plus "DIAG" screen controls to manually
power the header lower valve. Use a multimeter to check for 12 volts between connector X022 pin 5 and
chassis ground.
A.
If 12 volts is not present, there is an open circuit in the main frame (MF) harness between connector
X022 pin 5 and connector X019 pin J2-5 wire 1113 white. Locate the open and repair.
B.
If 12 volts is found, continue with Step 9.
7.
Visually inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or
broken wires.
A.
If no damage is found, erase the fault code and continue operation.
TOOL POSITIONING - LIFTING
9706 1 27/05/2004
G.10.A / 11