d: References

Reference parameters are used to set the various frequency reference values during operation.
No.
Name
d1-01
Frequency
Frequency reference
<22>
Reference 1
d1-02
Frequency
Frequency reference when digital input "Multi-Step
<22>
Reference 2
Speed Reference 1" (H1-oo = 3) is on.
d1-03
Frequency reference when digital input "Multi-Step
Frequency
<22>
Reference 3
Speed Reference 2" (H1-oo = 4) is on.
d1-04
Frequency
Frequency reference when digital inputs "Multi-Step
<22>
Reference 4
Speed Reference 1, 2" (H1-oo = 3 and 4) are on.
d1-05
Frequency
Frequency reference when digital input "Multi-Step
<22>
Reference 5
Speed Reference 3" (H1-oo = 5) is on.
d1-06
Frequency
Frequency reference when digital inputs "Multi-Step
<22>
Reference 6
Speed Reference 1, 3 " (H1-oo = 3 and 5) are on.
d1-07
Frequency
Frequency reference when digital inputs "Multi-Step
<22>
Reference 7
Speed Reference 2, 3" (H1-oo = 4 and 5) are on.
Frequency reference when multi-function input
d1-08
Frequency
"Multi-Step speed reference 1, 2, 3" (H1-oo = 3, 4,
<22>
Reference 8
5) are on.
Frequency reference when digital inputs "Jog
d1-17
Jog Frequency
Frequency Reference", "Forward Jog" or "Reverse
<22>
Reference
Jog." are on.
Sets the frequency reference upper limit as a
Frequency
percentage of maximum output frequency (E1-04).
d2-01
Reference
Output speed is limited to this value even if the
Upper Limit
frequency reference is higher. This limit applies to all
frequency reference sources.
Sets the frequency reference lower limit as a
Frequency
percentage of maximum output frequency (E1-04).
d2-02
Reference
Output speed is limited to this value even if the
Lower Limit
frequency reference is lower. This limit applies to all
frequency reference sources.
Use d3 parameters to configure the drive Jump Frequency settings.
d3-01 Jump
d3-01 to d3-04 allow programming of three prohibited
Frequency 1
frequency reference points for eliminating problems
with resonant vibration of the motor/machine. This
feature does not eliminate the selected frequency
values, but accelerates and decelerates the motor
Jump
d3-02
through the prohibited bandwidth.
Frequency 2
The parameters must be according to the rule
d3-01 ≥ d3-02 .
YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual
Description
d1: Frequency Reference
Use d1 parameters to configure the drive frequency reference.
d2: Frequency Upper and Lower Limits
Use d2 parameters to configure the frequency reference limits.
d3: Jump Frequency
B.2 Parameter Table
Mode Addr.
Range Def.
Hex
V/f
0.00
S
Hz
0.00
S
Hz
0.00
S
Hz
0.00
S
Hz
0.00 to
0.00
O
400.00
Hz
Hz
0.00
<19>
O
Hz
0.00
O
Hz
0.00
O
Hz
6.00
S
Hz
0.0 to
100.0
O
110.0
%
0.0 to
0.0%
O
110.0
0.0
O
Hz
0.0 to
400.0
0.0
O
Hz
Pg.
280
96
281
96
282
96
283
96
284
285
286
287
292
289
28A
294
295
B
203

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cimr-jt seriesJ1000 series

Table of Contents