5584, Eeprom Contains Blank Data - Beckhoff AX8000 User Information

Multi axis servo system diagnostic messages
Hide thumbs Also See for AX8000:
Table of Contents

Advertisement

3.7

5584, EEPROM contains blank Data

The Identity EEPROM of a Pcb is blank. (no Response)
- ID 0: ControlPcb
- ID 1: FrontPcb
- ID 2: AdditionalAxisPcb
- ID 3: DisplayPcb
- ID 6: SafetyPcb
- ID 7: CpuPcb
Diagnostic Code (Hex.)
5584
Class
Error
Standard Reaction
Axis is inoperable
Possible Causes
There is an internal hardware error.
Internal: 0x5584, EEPROM contains blank Data. Pcb ID %u.
Multi axis servo system - AX8000
Diagnostic Code (Dez.)
21892
Type
Error
Reset
A reset is not possible. The drive detected a fatal
hard- or software error.
Solutions
Send the AX8000 to the Beckhoff branch office that is
responsible for you.
Version: 1.1
Standard-Messages