All data valid for 40 °C ambient temperature and 60 K overtempera-
ture of the winding. The data can have a tolerance of +/- 10 %.
This chapter provides information on various technical terms and
their meaning.
Peak force F
[N]
max
Peak force at peak current I
pends on the peak output current of the servo drive used. The peak
force results in significant heating of the motor and may be delivered
permanently for a maximum of 5 seconds; S5 operation.
Peak current I
[A]
max
RMS value of the peak current at peak force F
Continuous force F
[N]
c
Available continuous force in S1 operation close to standstill at con-
tinuous current I
.
c
Continuous current I
[A]
c
RMS value of the continuous current at continuous force F
Maximum velocity V
max
Maximum velocity of the linear motor.
Force constant K
[N/A]
f
Ratio of force to current while maintaining the design air gap.