Diagmessages of module AsynchronousMotor
18.11
7183, Motor thermal utilization has reached the Error
Level
Diagnostic Code (Hex.)
7183
Class
Warning
Standard Reaction
No
Internal: 0x7183, Motor thermal utilization has reached the Error Level
240
Diagnostic Code (Dez.)
29059
Type
Warning
Reset
Warning: No reset required.
Version: 1.1