63Aa, Object Changed In Ethercat Safeop Or Op - Beckhoff AX8000 User Information

Multi axis servo system diagnostic messages
Hide thumbs Also See for AX8000:
Table of Contents

Advertisement

Diagmessages of module AxisMain
6.49

63AA, Object changed in EtherCAT SafeOP or OP.

This errormessage was created, because this change during Runtime is potentially dangerous, if you don't
know what you do.
Diagnostic Code (Hex.)
63AA
Class
Error
Standard Reaction
Axis is inoperable
Possible Causes
The value of the position range limit or a Factor group
object was changed in EtherCAT SafeOP or OP.
Internal: 0x63AA, Object 0x%X/%X changed in EtherCAT SafeOP or OP.
148
Diagnostic Code (Dez.)
25514
Type
Error
Reset
Execute Reset-Command (Fault reset).
Solutions
Execute fault reset command.