Technical Data; Data For Operation And Environment - Beckhoff AX8000 Series Operating Instructions Manual

Multi-axis servo system
Hide thumbs Also See for AX8000 Series:
Table of Contents

Advertisement

Technical data

Data for operation and
4.1
environment
Environmental requirements
Climate category - operation
Ambient temperature during operation
Ambient temperature during transport
Ambient temperature during storage
Power derating
Installation altitude
Permissible humidity in operation
Permissible humidity during transport and
storage
Corrosion protection
Level of contamination
Specifications for intended use
Ventilation
Insulation material class
Protection class
Installation position
Vibration resistance
Shock resistance
EMC requirements
Approvals
28
───
Operate servo drives only under the specified environmental
conditions
Operate the servo drives only in accordance with the specifications
for operation and the environment listed in this chapter. This en-
sures a long service life and proper operation.
The lifetime of the servo drive may be shortened at temperatures
above 40 °C and with encapsulated installation.
Beckhoff products are designed for operation under certain environ-
mental conditions, which vary according to the product. The follow-
ing specifications must be observed for operation and environment
in order to achieve the optimum service life of the products.
2K3 according to EN 60721
0 °C to +40 °C
Extended temperature range up to +55 °C with power derating of 2
% / K
-25 °C to +70 °C, maximum fluctuation 20 K per hour
-25 °C to +55 °C, maximum fluctuation 20 K per hour
No power derating up to 1000 m above sea level
Power derating of 1 % / 100 m from 1000 m up to maximally 3000
m
above sea level
A reduction of the overvoltage category is necessary from an in-
stallation altitude of 2000 m up to maximally 3000 m above sea
level. Observe derating.
15 % to 95 % relative humidity, no condensation
15 % to 85 % relative humidity, no condensation
Not required:
Special measures are to be taken in consultation with the vendor if
the environmental conditions are extreme or if they differ from
those described in this chapter.
2 according to EN 60204 and EN 50178
Integrated and temperature-controlled fan
F according to IEC 60085 and UL1446 class F
Devices IP 20
Terminals IP 00
Vertical
1 G, 150 Hz according to EN 61800-5-1
5 G, 30 ms according to EN 60068-2-27
conforms to EN 61800-3:2004 + A1:2012
CE
cULus
EAC
See chapter: "Guidelines and Standards", [Page 87]
AX8000
Version: 1.1

Hide quick links:

Advertisement

Table of Contents
loading