6.6

2383, Phase U current offset out of range

The measured current offset of Phase U is outside the accepted range.
Diagnostic Code (Hex.)
2383
Class
Error
Standard Reaction
Torque off
Possible Causes
An unknown hard- or software error has occurred.
Internal: 0x2383, Phase U current offset out of range
Multi axis servo system - AX8000
Diagnostic Code (Dez.)
9091
Type
Error
Reset
Execute Reset-Command (Fault reset).
Solutions
Disconnect the power supply module from the mains
(including the 24 V power supply) and start a new
attempt. If this error occurs repeatedly, please call
the Beckhoff support that is responsible for you.