3.41

A00E, Dynamic Sync Manager Address Error.

Diagnostic Code (Hex.)
A00E
Class
Warning
Standard Reaction
No
Possible Causes
The Parameters of the CoE Communication Objects
do not fit the Sync Manager Parameters.
Internal: 0xA00E, Dynamic Sync Manager %u Address Error. Requested Address=0x%x is not between
Min=0x%x and Max=0x%x
Multi axis servo system - AX8000
Diagnostic Code (Dez.)
40974
Type
Warning
Reset
Warning: No reset required.
Solutions
Please check, if you are working with the right
EtherCAT Device Description XML-File.