Diagmessages Of Module Velocitycontrol2; 3183, The Bipolar Velocity Limit Is Higher Than 1/4 Of Position Range Limit Per Ethercat Sync1 Cycle - Beckhoff AX8000 User Information

Multi axis servo system diagnostic messages
Hide thumbs Also See for AX8000:
Table of Contents

Advertisement

Diagmessages of module VelocityControl2

10
Diagmessages of module VelocityControl2
10.1
3183, The bipolar velocity limit is higher than 1/4 of
position range limit per EtherCAT Sync1 cycle.
The maximum accepted position step per cycle is 1/4 of the position range limit range. This error occurs, if
the resulting velocity is lower than the bipolar velocity limit.
Diagnostic Code (Hex.)
3183
Class
Error
Standard Reaction
Closed loop ramp
Possible Causes
The maximum accepted position step per cycle is 1/4
of the position range limit range. This error occurs, if
the resulting velocity is lower than the bipolar velocity
limit.
Internal: 0x3183, The bipolar velocity limit is higher than 1/4 of position range limit per EtherCAT Sync1
cycle.
178
Diagnostic Code (Dez.)
12675
Type
Error
Reset
Execute Reset-Command (Fault reset).
Solutions
Raise your position range limit or lower your bipolar
velocity limit.
Version: 1.1