3180, Phase Failure Motor - Beckhoff AX8000 User Information

Multi axis servo system diagnostic messages
Hide thumbs Also See for AX8000:
Table of Contents

Advertisement

Diagmessages of module AxisMain
6.9

3180, Phase failure motor

The drive software detected an phase failure at the motor side. Please check wiring.
Diagnostic Code (Hex.)
3180
Class
Error
Standard Reaction
Shorted coils brake
Possible Causes
A power wire is not connected properly to the hybrid
motor connector.
The hybrid motor connector seems not to be plugged
in properly.
A power wire in the motor cable is broken.
Internal: 0x3180, Phase failure motor
108
Diagnostic Code (Dez.)
12672
Type
Motor connection error
Reset
Execute Reset-Command (Fault reset).
Solutions
Check the power connections to the hybrid motor
connector.
Check if the hybrid motor connector is plugged in
properly.
Check the power wires in the motor cable.
Version: 1.1