6183, Internal Watchdog Error - Beckhoff AX8000 User Information

Multi axis servo system diagnostic messages
Hide thumbs Also See for AX8000:
Table of Contents

Advertisement

Diagmessages of module AxisMain
6.21

6183, Internal Watchdog Error

Diagnostic Code (Hex.)
6183
Class
Error
Standard Reaction
Closed loop ramp
Possible Causes
To much objects in the PDO-mapping.
An unknown hard- or software error has occurred.
Internal: 0x6183, Internal Watchdog Error
120
Diagnostic Code (Dez.)
24963
Type
Error
Reset
Execute Reset-Command (Fault reset).
Solutions
Check the number of objects in the PDO-mapping.
Disconnect the power supply module from the mains
(including the 24 V power supply) and start a new
attempt. If this error occurs repeatedly, please call
the Beckhoff support that is responsible for you.
Version: 1.1