7180, Motor Brake: Current Monitoring Error - Beckhoff AX8000 User Information

Multi axis servo system diagnostic messages
Hide thumbs Also See for AX8000:
Table of Contents

Advertisement

6.50

7180, Motor brake: Current monitoring error.

The motor brake current monitoring detected an insufficient current.
Diagnostic Code (Hex.)
7180
Class
Error
Standard Reaction
Closed loop ramp
Possible Causes
You have configured a motor brake and the motor
brake current fell below the motor brake current
monitoring level.
Internal: 0x7180, Motor brake: Current monitoring error.
Multi axis servo system - AX8000
Diagnostic Code (Dez.)
29056
Type
Motor Brake connection error
Reset
Execute Reset-Command (Fault reset).
Solutions
Check your motor brake connection (wires and
connectors). Check the parameter 'motor brake
current monitoring level' Object 0x3000/5 (Ch A) or
Object 0x3400/5 (Ch B).
Version: 1.1
Diagmessages of module AxisMain
149