6.34
639B, additional Factor Group Parameters: Position
encoder resolution illegal motor revolutions
The actual combination of the factor group Parameters is not allowed for this Device.
Diagnostic Code (Hex.)
639B
Class
Error
Standard Reaction
Axis is inoperable
Possible Causes
The additional position encoder resolution - motor
revolutions contains an illegal value (Object
0x60EB/1 ChA or 0x68EB/1 ChB).
Internal: 0x639B, additional Factor Group Parameters: Position encoder resolution illegal motor revolutions
Multi axis servo system - AX8000
Diagnostic Code (Dez.)
25499
Type
Error
Reset
Execute Reset-Command (Fault reset).
Solutions
Please compare it to your encoder values.