8780, Configured Sync1 Cycle Time Is Above Maximum - Beckhoff AX8000 User Information

Multi axis servo system diagnostic messages
Hide thumbs Also See for AX8000:
Table of Contents

Advertisement

4.11

8780, Configured Sync1 Cycle Time is above Maximum

The configured Sync1 Cycle Time is above the maximum.
Diagnostic Code (Hex.)
8780
Class
Error
Standard Reaction
Axis is inoperable
Possible Causes
The Cycle Time of your NC-Task is above the
supported maximum value of this drive.
Internal: 0x8780, Sync Controller: Configured Sync1 Cycle Time (%u ns) is above Maximum (%u ns).
Multi axis servo system - AX8000
Diagmessages of module DeviceMain
Diagnostic Code (Dez.)
34688
Type
Error
Reset
Execute Reset-Command (Fault reset).
Solutions
Please set your Task to a shorter Cycle Time.