6181, Internal Software Error Type B - Beckhoff AX8000 User Information

Multi axis servo system diagnostic messages
Hide thumbs Also See for AX8000:
Table of Contents

Advertisement

Standard-Messages
3.20

6181, Internal Software Error Type B

Fatal Software Error.
Diagnostic Code (Hex.)
6181
Class
Error
Standard Reaction
Open loop ramp
Possible Causes
Fatal Software Exception Error.
Internal: 0x6181, Internal Software Error Type B, Additional Errorcode 0x%x
34
Diagnostic Code (Dez.)
24961
Type
Error
Reset
Execute Reset-Command (Fault reset).
Solutions
Please switch the 24 V supply off and on again. If this
happens again, contact the Beckhoff branch office
that is responsible for you.
Version: 1.1
Multi axis servo system - AX8000

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents