2384, Phase V Current Offset Out Of Range - Beckhoff AX8000 User Information

Multi axis servo system diagnostic messages
Hide thumbs Also See for AX8000:
Table of Contents

Advertisement

Diagmessages of module AxisMain
6.7

2384, Phase V current offset out of range

The measured current offset of Phase V is outside the accepted range.
Diagnostic Code (Hex.)
2384
Class
Error
Standard Reaction
Torque off
Possible Causes
An unknown hard- or software error has occurred.
Internal: 0x2384, Phase V current offset out of range
106
Diagnostic Code (Dez.)
9092
Type
Error
Reset
Execute Reset-Command (Fault reset).
Solutions
Disconnect the power supply module from the mains
(including the 24 V power supply) and start a new
attempt. If this error occurs repeatedly, please call
the Beckhoff support that is responsible for you.
Version: 1.1
Multi axis servo system - AX8000

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents