63A8, Position Range Limit Inc With Remainder Is Not Supported For Primary Feedback - Beckhoff AX8000 User Information

Multi axis servo system diagnostic messages
Hide thumbs Also See for AX8000:
Table of Contents

Advertisement

Diagmessages of module AxisMain
6.47
63A8, Position range limit Inc with remainder is not
supported for primary feedback.
The position range limit is scaled internally to encoder increments. This calculation result contains a
remainder, which is not supported for the primary feedback.
Diagnostic Code (Hex.)
63A8
Class
Error
Standard Reaction
Axis is inoperable
Possible Causes
The position range limit is scaled internally to encoder
increments. This calculation result contains a
remainder, which is not supported for the primary
feedback.
Internal: 0x63A8, Position range limit Inc with remainder is not supported for primary feedback.
146
Diagnostic Code (Dez.)
25512
Type
Error
Reset
Execute Reset-Command (Fault reset).
Solutions
Please check the position range limit and the factor
group parameters of this feedback.