Scaling Index Object Does Not Fit The Factor Group Parameters For The First Encoder - Beckhoff AX8000 User Information

Multi axis servo system diagnostic messages
Hide thumbs Also See for AX8000:
Table of Contents

Advertisement

Diagmessages of module AxisMain
6.37
639E, Scaling index object does not fit the Factor
group parameters for the first Encoder
The actual combination of the factor group Parameters is not allowed for this Device.
Diagnostic Code (Hex.)
639E
Class
Error
Standard Reaction
Axis is inoperable
Possible Causes
The mentioned scaling index object doesn't represent
the factor group settings of the first encoder.
Internal: 0x639E, Scaling index object 0x%x does not fit the Factor group parameters for the first Encoder
136
Diagnostic Code (Dez.)
25502
Type
Error
Reset
Execute Reset-Command (Fault reset).
Solutions
Please compare the selected scaling to your factor
group settings.
Version: 1.1