3.35
A003, Transition Pre-Op to Safe-Op not successful.
Sync Manager Address Range overlap.
Diagnostic Code (Hex.)
A003
Class
Error
Standard Reaction
Axis is inoperable
Possible Causes
The Parameters of the CoE Communication Objects
do not fit the Sync Manager Parameters.
Internal: 0xA003, Transition Pre-Op to Safe-Op not successful. Sync Manager %u Address Range 0x%x..0x
%x overlaps Sync Manager %u Address Range 0x%x..0x%x
Multi axis servo system - AX8000
Diagnostic Code (Dez.)
40963
Type
Error
Reset
Execute Reset-Command (Fault reset).
Solutions
Please check, if you are working with the right
EtherCAT Device Description XML-File.
Version: 1.1