63A3, Offset Additional Position Actual Value: No Position Offset Existing In Source 'Encoder Memory - Beckhoff AX8000 User Information

Multi axis servo system diagnostic messages
Hide thumbs Also See for AX8000:
Table of Contents

Advertisement

6.42
63A3, Offset additional position actual value: No
position offset existing in source 'encoder memory'
There is no secondary position offset stored, for the selected source 'encoder memory'.
Diagnostic Code (Hex.)
63A3
Class
Error
Standard Reaction
Axis is inoperable
Possible Causes
A position offset should used in the position control
loop, but no position offset has been saved.
Internal: 0x63A3, Offset additional position actual value: No position offset existing in source 'encoder
memory'
Multi axis servo system - AX8000
Diagnostic Code (Dez.)
25507
Type
Error
Reset
Execute Reset-Command (Fault reset).
Solutions
Calibrate the axis and save the new position offset.