Diagmessages of module SyncServoMotor
16.4
638B, Parameter Torque Current curve: Unable to
calculate Torque Current curve.
The characteristic is not monotonically increasing or not in the right working range.
Diagnostic Code (Hex.)
638B
Class
Error
Standard Reaction
Shorted coils brake
Possible Causes
The characteristic is not monotonically increasing or
not in the right working range.
Internal: 0x638B, Parameter Torque Current curve: Unable to calculate Torque Current curve.
216
Diagnostic Code (Dez.)
25483
Type
Error
Reset
Execute Reset-Command (Fault reset).
Solutions
Check the configured motor and the torque current
curve.