Technical Description; Mounting Position; Feedback - Beckhoff AMI8100 Operating Instructions Manual

Compact integrated servo drives
Hide thumbs Also See for AMI8100:
Table of Contents

Advertisement

Mounting position

7.1

Feedback

7.2
Feedback
Resolution
Encoder, single-turn
17-bit
Encoder, multi-turn
Version: 1.0
Observe the maintenance intervals and installation positions
Carry out maintenance at regular intervals.
In the horizontal installation position IM V3, liquid which has been
left on the flange for a longer period can penetrate the servo drive
through capillary action. In installation position IM V1 liquid can es-
cape.
If you do not observe the maintenance intervals, the servo drive
may overheat depending on the installation position. Ingress and
leakage of liquids may damage the servo drive.
The standard installation position of the servo drives is the design
IM B5 according to DIN EN 60034-7.
Feedback exchange
The feedback system installed can only be replaced with an identi-
cal system. It is not possible to change the feedback system retro-
spectively.
The table below provides information about system accuracies and
resolutions of the servo drive feedback systems:
System accuracy
± 316 angular seconds
AMI8100

Technical description

Comment
Standard:
AMI812x
───
35

Advertisement

Table of Contents
loading

Table of Contents