Juniper ACX1000 Configuration Manual page 2011

Junos os; acx series universal access router
Hide thumbs Also See for ACX1000:
Table of Contents

Advertisement

show chassis environment (ACX2000 Universal Access Router)
show chassis environment (ACX4000 Universal Access Router)
Copyright © 2017, Juniper Networks, Inc.
SIB 3 PF0 Temp Sensor
SIB 3 PF1 Temp Sensor
SIB 4 Intake-A Temp Sensor
SIB 4 Intake-B Temp Sensor
SIB 4 Exhaust-A Temp Sensor
SIB 4 Exhaust-B Temp Sensor
SIB 4 PF0 Temp Sensor
SIB 4 PF1 Temp Sensor
SIB 5 Intake-A Temp Sensor
SIB 5 Intake-B Temp Sensor
SIB 5 Exhaust-A Temp Sensor
SIB 5 Exhaust-B Temp Sensor
SIB 5 PF0 Temp Sensor
SIB 5 PF1 Temp Sensor
Power Power Supply 0
Power Supply 1
Power Supply 2
Power Supply 3
Power Supply 4
Power Supply 5
Fans
Fan Tray 0 Fan 0
Fan Tray 0 Fan 1
Fan Tray 0 Fan 2
Fan Tray 0 Fan 3
Fan Tray 0 Fan 4
Fan Tray 0 Fan 5
Fan Tray 0 Fan 6
Fan Tray 0 Fan 7
Fan Tray 0 Fan 8
Fan Tray 0 Fan 9
Fan Tray 0 Fan 10
Fan Tray 1 Fan 0
Fan Tray 1 Fan 1
Fan Tray 1 Fan 2
Fan Tray 1 Fan 3
Fan Tray 1 Fan 4
Fan Tray 1 Fan 5
Fan Tray 1 Fan 6
Fan Tray 1 Fan 7
Fan Tray 1 Fan 8
Fan Tray 1 Fan 9
Fan Tray 1 Fan 10
user@host> show chassis environment
Class Item
PCB Left
SFP+ Xcvr
FEB
PCB Up
PCB Mid
Telecom Mod
Routing Engine
Heater off
On the ACX4000 router, the MIC output of the
varies depending on the number of temperature channels present in the installed MIC.
Chapter 42: Operational Commands
OK
54 degrees C / 129 degrees F
OK
42 degrees C / 107 degrees F
OK
46 degrees C / 114 degrees F
OK
34 degrees C / 93 degrees F
OK
36 degrees C / 96 degrees F
OK
46 degrees C / 114 degrees F
OK
54 degrees C / 129 degrees F
OK
41 degrees C / 105 degrees F
OK
38 degrees C / 100 degrees F
OK
31 degrees C / 87 degrees F
OK
34 degrees C / 93 degrees F
OK
39 degrees C / 102 degrees F
OK
44 degrees C / 111 degrees F
OK
42 degrees C / 107 degrees F
OK
OK
OK
OK
Check
OK
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
Failed
Failed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
Status
Measurement
OK
44 degrees C / 111 degrees F
OK
50 degrees C / 122 degrees F
OK
70 degrees C / 158 degrees F
OK
63 degrees C / 145 degrees F
OK
66 degrees C / 150 degrees F
OK
65 degrees C / 149 degrees F
OK
54 degrees C / 129 degrees F