Initializing Parameter Settings (Fn005) - YASKAWA SGMJV User Manual

Rotational motor mechatrolink-ii communications reference
Hide thumbs Also See for SGMJV:
Table of Contents

Advertisement

6 Utility Functions (Fn)
6.6

Initializing Parameter Settings (Fn005)

This function is used when returning to the factory settings after changing parameter settings.
Note: Any value adjusted with Fn00C, Fn00D, Fn00E, and Fn00F cannot be initialized by Fn005.
(1) Preparation
The following conditions must be met to initialize the parameter values.
• The write prohibited setting (Fn010) must be set to Write permitted (P.0000).
• The servomotor power must be OFF.
(2) Operating Procedure
Use the following procedure.
Step
1
2
3
4
6-12
• Be sure to initialize the parameter settings while the servomotor power is OFF
• After initialization, turn OFF the power supply and then turn ON again to validate the
settings.
Display after Operation
− F U N C T I O N −
B B
F n 0 0 4 : P r o g r a m J O G
F n 0 0 5 : P r m I n i t
F n 0 0 6 : A l m H i s t C l r
F n 0 0 8 : M t u r n C l r
B B
P a r a m e t e r l n i t
S t a r t
: [ D A T A ]
R e t u r n : [ S E T ]
B B
P a r a m e t e r l n i t
S t a r t
: [ D A T A ]
R e t u r n : [ S E T ]
To enable the setting, turn the power supply to the SERVOPACK OFF and ON again.
Keys
Press the
utility function.
Use the
or
select Fn005.
Press the
execution display.
Press the
During initialization, "Parameter Init" is flashing in
the display.
After the initialization is completed, "Parameter Init"
stops flashing and the status display changes as fol-
lows: "BB" to "DONE" to "BB."
Note:
Press the
display returns to the main menu of the utility func-
tion.
Operation
Key to view the main menu for the
Key to move through the list and
Key. The display changes to the Fn005
Key to initialize parameters.
Key not to initialize parameters. The
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgmavSgmcsSgmpsSgmgvSgmsv

Table of Contents