YASKAWA SGMJV User Manual page 350

Rotational motor mechatrolink-ii communications reference
Hide thumbs Also See for SGMJV:
Table of Contents

Advertisement

Parameter
Size
No.
2
Input Signal Selection 2
4th 3rd 2nd 1st
digit digit digit digit
n.    
Pn50B
Setting
Name
Range
0000 to FFFF
N-OT Signal Mapping
0
Reverse run allowed when CN1-13 input signal is ON (closed).
1
Reverse run allowed when CN1-7 input signal is ON (closed).
2
Reverse run allowed when CN1-8 input signal is ON (closed).
3
Reverse run allowed when CN1-9 input signal is ON (closed).
4
Reverse run allowed when CN1-10 input signal is ON (closed).
5
Reverse run allowed when CN1-11 input signal is ON (closed).
6
Reverse run allowed when CN1-12 input signal is ON (closed).
7
Reverse run prohibited.
8
Reverse run allowed.
9
Reverse run allowed when CN1-13 input signal is OFF (open).
A
Reverse run allowed when CN1-7 input signal is OFF (open).
B
Reverse run allowed when CN1-8 input signal is OFF (open).
C
Reverse run allowed when CN1-9 input signal is OFF (open).
D
Reverse run allowed when CN1-10 input signal is OFF (open).
E
Reverse run allowed when CN1-11 input signal is OFF (open).
F
Reverse run allowed when CN1-12 input signal is OFF (open).
Reserved (Do not change.)
/P-CL Signal Mapping
0
Active when CN1-13 input signal is ON (closed).
1
Active when CN1-7 input signal is ON (closed).
2
Active when CN1-8 input signal is ON (closed).
3
Active when CN1-9 input signal is ON (closed).
4
Active when CN1-10 input signal is ON (closed).
5
Active when CN1-11 input signal is ON (closed).
6
Active when CN1-12 input signal is ON (closed).
7
Always active (fixed).
8
Not active (fixed).
9
Active when CN1-13 input signal is OFF (open).
A
Active when CN1-7 input signal is OFF (open).
B
Active when CN1-8 input signal is OFF (open).
C
Active when CN1-9 input signal is OFF (open).
D
Active when CN1-10 input signal is OFF (open).
E
Active when CN1-11 input signal is OFF (open).
F
Active when CN1-12 input signal is OFF (open).
/N-CL Signal Mapping
0 to F
Same as /P-CL signal mapping
Factory
When
Units
Setting
Enabled
8882
After restart
10.1 List of Parameters
(cont'd)
Reference
Classification
Section
Setup
Reference
Section
4.3.2
Reference
Section
4.6.2
Reference
Section
4.6.2
10-17
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgmavSgmcsSgmpsSgmgvSgmsv

Table of Contents