3.2.5

Initializing Parameter Settings (Fn005)

This function is used when returning to the factory settings after changing parameter
settings.
Note: Any value adjusted with Fn00C, Fn00D, Fn00E, and Fn00F cannot be initialized by
Fn005.
(1)
Preparation
The following conditions must be met to initialize the parameter values.
• The write prohibited setting (Fn010) must not be set to write-protect parameters.
• The servomotor power must be OFF.
(2)
Operating Procedure
Use the following procedure.
Step
Display after Operation
1
2
• Be sure to initialize the parameter settings while the servo-
motor power is OFF
• After initialization, turn OFF the power supply and then
turn ON again to validate the settings.
Keys
.
Operation
Press the
Key to view the main
menu for the utility function mode.
Use the
or
through the list and select Fn005.
Press the
Key. The display
changes to the Fn005 execution dis-
play.
3.2 Operations
Key to move
9 3
3-17