(5) Power Supply Capacities and Power Losses
The following table shows SERVOPACK's power supply capacities and power losses when using single-
phase 200 V power supply.
Maximum
Main Circuit
Applicable
Power
Servomotor
Supply
Capacity
[kW]
0.05
0.1
0.2
Single-phase,
200 V
0.4
0.75
1.5
The official model number is SGDV-120A11A008000.
Note 1. SGDV-R70A, -R90A, -1R6A, and -2R8A SERVOPACKs do not have built-in regenerative resistors. If the regen-
erative energy exceeds the specified value, connect an external regenerative resistor between B1/
2. Regenerative resistor power losses are allowable losses. Take the following action if this value is exceeded.
• Remove the lead or shorting bar between terminals B2 and B3 on the SERVOPACK main circuit of SGDV-
5R5A, -120A SERVOPACKs.
• Install an external regenerative resistor between external regenerative resistor connection terminals B1/
B2.
3. External regenerative resistors are not included.
(6) How to Select Molded-case Circuit Breaker and Fuse Capacities
The following table shows the SERVOPACK's current capacities and inrush current when using single-phase
Use these values as a basis for selecting the molded-case circuit breaker and fuse.
Maximum
Main Circuit
Applicable
Power
Servomotor
Supply
Capacity
[kW]
0.05
0.1
Single-
0.2
phase,
0.4
200 V
0.75
1.5
The official model number is SGDV-120A11A008000.
Note 1. To comply with the EU low voltage directive, connect a fuse to the input side as protection against accidents
caused by short-circuits. Select the fuse for the input side that are compliant with UL standards.
The table above also provides the net values of current capacity and inrush current. Select a fuse and a molded-
case circuit breaker which meet the breaking characteristics shown below.
• Main circuit, control circuit: No breaking at three times the current values shown in the table for 5 s.
• Inrush current: No breaking at the current values shown in the table for 20 ms.
2. The following restrictions apply to UL standard compliance conditions for SGDV-120A11A008000 SERVO-
PACKs.
• Current rating when using molded-case circuit breaker: 40 A max.
Power Supply
SERVOPACK
Capacity per
Model SGDV-
SERVOPACK
[kVA]
R70A
0.2
R90A
0.3
1R6A
0.7
2R8A
1.2
5R5A
1.9
*
4
120A
Power Supply
SERVOPACK
Capacity per
Model
SERVOPACK
SGDV-
[kVA]
R70A
0.2
R90A
0.3
1R6A
0.7
2R8A
1.2
5R5A
1.9
*
4
120A
Main
Regenerative
Output
Circuit
Resistor
Current
Power
Power Loss
[Arms]
Loss
[W]
[W]
0.66
5.2
0.91
7.4
1.6
13.7
2.8
24.9
5.5
52.7
8
11.6
68.2
10
Current Capacity
Main
Control
Circuit
Circuit
[Arms]
[Arms]
2
2
3
0.2
5
9
16
0.25
3.1 Main Circuit Wiring
Control
Total
Circuit
Power
Power
Loss
Loss
[W]
[W]
22.2
24.4
17
30.7
41.9
77.7
22
100.2
and B2.
and
Inrush Current
Main
Control
Circuit
Circuit
[A0-p]
[A0-p]
70
33
33
3
3-13