YASKAWA SGMJV User Manual page 353

Rotational motor mechatrolink-ii communications reference
Hide thumbs Also See for SGMJV:
Table of Contents

Advertisement

10 Appendix
Parameter
Size
No.
2
Input Signal Selection 5
4th 3rd 2nd 1st
digit digit digit digit
n.    
Pn511
10-20
Setting
Name
Range
0000 to FFFF
Homing Deceleration Switch Signal Mapping (/DEC)
0
Active when CN1-13 input signal is ON (closed).
1
Active when CN1-7 input signal is ON (closed).
2
Active when CN1-8 input signal is ON (closed).
3
Active when CN1-9 input signal is ON (closed).
4
Active when CN1-10 input signal is ON (closed).
5
Active when CN1-11 input signal is ON (closed).
6
Active when CN1-12 input signal is ON (closed).
7
Always active.
8
Always not active.
9
Active when CN1-13 input signal is OFF (open).
A
Active when CN1-7 input signal is OFF (open).
B
Active when CN1-8 input signal is OFF (open).
C
Active when CN1-9 input signal is OFF (open).
D
Active when CN1-10 input signal is OFF (open).
E
Active when CN1-11 input signal is OFF (open).
F
Active when CN1-12 input signal is OFF (open).
External Latch Signal Mapping (/EXT1)
0 to 3
Always not active.
4
Active when CN1-10 input signal is ON (closed).
5
Active when CN1-11 input signal is ON (closed).
6
Active when CN1-12 input signal is ON (closed).
7 to C
Always not active.
D
Active when CN1-10 input signal is OFF (open).
E
Active when CN1-11 input signal is OFF (open).
F
Active when CN1-12 input signal is OFF (open).
External Latch 2 Signal Mapping (/EXT2)
0 to F
Same as /EXT1 signal mapping.
External Latch 3 Signal Mapping (/EXT3)
0 to F
Same as /EXT1 signal mapping.
Factory
When
Units
Setting
Enabled
6543
After restart
(cont'd)
Reference
Classification
Section
Setup
3.3.1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgmavSgmcsSgmpsSgmgvSgmsv

Table of Contents