10 Appendix
Parameter
Size
No.
Application Function Select
2
Switch B
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn00B
Application Function Select
2
Switch C
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn00C
Application Function Select
2
Switch D
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn00D
10-6
Setting
Name
Range
0000 to 1111
Parameter Display Selection
0
Setup parameters
1
All parameters
Alarm Gr.2 Stop Method Selection
0
Stops the motor by setting the speed reference to "0".
1
Same setting as Pn001.0 (Stops the motor by applying DB or by coasting).
Power Supply Method for Three-phase SERVOPACK
0
Three-phase power supply
1
Single-phase power supply
Reserved (Do not change.)
0000 to 0111
Selection of Test without a Motor
0
Disables test without a motor.
1
Enables test without a motor.
Encoder Resolution for Test without a Motor
0
13 bits
1
20 bits
Encoder Type for Test without a Motor
0
Incremental encoder
1
Absolute encoder
Reserved (Do not change.)
0000 to 1001
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Overtravel Warning Detection Selection
0
Does not detect overtravel warning.
1
Detects overtravel warning.
Factory
When
Units
Setting
Enabled
−
0000
After restart
−
0000
After restart
−
0000
Immediately
(cont'd)
Reference
Classification
Section
−
Setup
Reference
Section
2.4.1
Reference
Section
4.3.5
Reference
Section
3.1.3
4.5,
Setup
4.5.1
Setup
–
Reference
Section
4.3.2