(3) SERVOPACKs: Model SGDV-470A, -550A, -590A, -780A, -210D, -260D, -280D, -
370D
No built-in regenerative resistor is provided, so the external regenerative resistor is required. The regenerative
resistor units are as follows:
Note: The regenerative resistor unit is constructed from a number of resistors.
Main Circuit
SERVOPACK Model
Power Supply
470A
Three-phase
200 V
550A, 590A, 780A
210D, 260D
Three-phase
400 V
280D, 370D
Connect the B1/
and B2 terminals of the SERVOPACK to the R1 and R2 terminals of the regenerative resis-
tor unit.
Use Pn600 at the factory setting when you use a Yaskawa regenerative resistor unit. Set Pn600 when using a
non-YASKAWA external regenerative resistor.
Regenerative Resistor Unit
JUSP-RA
-E
Applicable
Applicable
Regenerative
SGDV-
Resistor Unit
JUSP-RA04-E
JUSP-RA05-E
JUSP-RA18-E
JUSP-RA19-E
SERVOPACK
3.7 Connecting Regenerative Resistors
Resis-
Specifications
tance (Ω)
Four 25 Ω (220 W) resistors are connected
6.25
in parallel.
Eight 25 Ω (220 W) resistors are connected
3.13
in parallel.
Two series of two 18 Ω (220 W) resistors
18
each are connected in parallel.
Four series of two 28.5 Ω (220 W) resistors
14.25
each are connected in parallel.
3
3-31